- Repair service
- Frequency inverter
- Electronic components
- KEB accessories
- Company
Filter products
16E4T60-1071 KEBEA-Filter 33A EA-FILTER-GEH:G 500V/33AEN55011-B DU/DT:500V/USFMAX = 400HZ BEI FS=4KHZTMAX = 45 GRAD CMOTOR LINE: 1 X 50MOUTPUT CURRENT: 30MA
18U5B0G-3000 KEBHF filter 18E5T60-1001 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 30 mANominal input current (Std): 65.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 181 x 424 x 65 mm
15E5T60-A071 KEBEA-Filter 24A EA-FILTER-GEH:E 500V/24AEN55011-B DU/DT:500V/μS50M MOTORL./ABL.I=20MAFMAX = 100HZ BEI FS=2KHZFOR FU 15F5 E-GEH.SPECIAL HOUSING
15E5T60-10G1 KEBEA-Filter I/O-Filters - Radio interference suppression filter according to EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 50 m to 4 kHzNominal input current (Std): 32.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHMax. Output frequency: 0...200HZOutput voltage range (Std): 0...550VRated output current (Std): 24.0AInductance: 0.72mHDimensions(WxHxD): 130 x 360 x 85 mm
19E5T60-1011 KEBNHF filter NHF side-mounted versionNHF filter Combination EMC filter EN 55011/ level B and mains choke uk=4% 400V classPn=30kWIn=66ADimensions 340x110x210 in mm
17U5B0G-3000 KEBHF filter 16E5T60-1002 HF - Radio interference suppression filter according to EN 61800-3for conducted interferenceTechnical data:C1 - max. Motor cable length 30 m to 16 kHzLeakage current: 17 mANominal input current (Std): 50.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 181 x 415 x 56 mm
17U5B0G-3030 KEBHF filter 17U5T60-10F1 Radio interference suppression filter in accordance with EN 55011/Bfor conducted interferencefor sub/additional installation on KEB COMBIVERT 17.F5. 3 x 400 VFilter current 3 x 50 AIT mains (low leakage currents) 10 mDimensions W x H x D: 181 x 415 x 56mm
0090425-4162 KEBDU/DT filter 33A/500V with DC link clamping
0090425-4133 KEBDU/DT Filter Umax= 500V Fmax= 800Hz With ZK feedback ABM: 340x75x175 mm Weight: 10kG
15U5B3E-3050 KEBEA-Filter 15E5T60-1071 EN55011-B DU/DT: 500V/US FMAX = 400HZ at FS=4KHZ TMAX = 45 degrees C Motor cable: 1 x 50 m
16Z1G04-1000 KEBSine filter FMAX = 100HZ UMAX = 500V IN = 33A @ 45°C FS = 4-16KHZ Terminal: 6x16mm², PE M6
18U5B0H-3000 KEBHF filter 18E4T60-1001 Radio interference suppression filter in accordance with EN 55011/Bfor conducted interferencefor installation alongside/substructure of KEB COMBIVERT 18.F5. 3 x 400VFilter current 3 x 65 ADimensions W x H x D: 300 x 445 x 66mm
18U5B0H-3030 KEBHF filter 18E5T60-10F1 Radio interference suppression filter in accordance with EN 55011/Bfor conducted interferencefor installation alongside/substructure of KEB COMBIVERT 18.F5. 3 x 400VFilter current 3 x 65 AIT mains (low leakage currents) 10 mDimensions W x H x D: 300 x 445 x 66mm
19U5B0H-3030 KEBHF filter 19E5T60-10F1 Radio interference suppression filter according to EN 55011/Bfor line-bound interferencefor adjacent/substructure mounting on KEB COMBIVERT 19.F5. 3 x 400VFilter current 3 x 90 AIT mains (low leakage currents) 10 mDimensions W x H x D: 300 x 445 x 66mm
19U5B0H-3000 KEBHF filter 19E5T60-1001 KEB COMBILINEHF - Radio interference suppression filter according to EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 16 mANominal input current (Std): 90.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 300 x 445 x 66 mm
23U5B0R-3000 KEBHF filter 22E4T60-1001 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 48 mANominal input current (Std): 165AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 270 x 419 x 64 mm
20U5B0R-3000 KEBHF filter 20E4T60-1001 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 48 mANominal input current (Std): 110AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 270 x 419 x 64 mm
20U5B0H-3000 KEBHF-FILTER 20E5T60-1002 HF - Radio interference suppression filter according to EN 61800-3for conducted interferenceTechnical data:C1 - max. Motor cable length 30 m to 16 kHzLeakage current: 15 mANominal input current (Std): 100AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 300 x 445 x 75 mm
09U5B0A-3000 KEB HF filter 09E5T60-1001 FILTER 09.E5.T60-1001WITH ADDITIONAL KITEN 55011-B05-09.F5 3 X 380...480VSUB-ASSEMBLY VERSION
16U5B0E-3030 KEB HF filter 16E5T60-10F1 With mounting kit EN 55011-B 16.F4 380...480 V substructure/substructure version
16U5B0E-3000 KEB HF filter 16E5T60-1001 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m to 16 kHzLeakage current: 10 mANominal input current (Std): 43AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 132 x 352 x 50 mm
15U5B0E-3030 KEB HF filter 15E5T60-10F1 Radio interference suppression filter in accordance with EN 55011/Bfor conducted interferencefor installation alongside/substructure on KEB COMBIVERT 15.F5. 3 x 400 VFilter current 3 x 30 Amax. motor cable 10 mIT mains (low leakage currents) 10 mDimensions W x H x D: 132 x 352 x 50mm
15U5B0E-3000 KEB HF filter 15E4T60-1001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 17 mANominal input current (Std): 30.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 132 x 352 x 50 mm
14U5B0E-3030 KEB HF filter 14E5T60-10F1 internal RFI filter in accordance with EN 55011/Bfor conducted interferencefor substructure on KEB COMBIVERT 14.F5. 3 x 400 VFilter current 22 Amax. motor cable 10 mIT mains (low leakage currents) 10 m