COMBILINE
Los filtros CEM del lado de la red – reducen las emisiones relacionadas con la potencia a los valores límite exigidos IEC61800…- C1/C2. Otras variantes ofrecen corrientes de fuga especialmente pequeñas o funcionamiento con formas de red especiales.
- Servicio de reparaciones
- Convertidor de frecuencia
- Componentes electrónicos
- Accesorios KEB
- Empresa
Filtro
14U5B0E-3000 KEB HF filter 14E4T60-1001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 17 mANominal input current (Std): 20.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 132 x 50 x 352 mm
10U5B0D-1010 KEB HF filter 10E5T60-0062 HF interference suppression filter according to EN 61800-3for conducted interferenceTechnical data:Nominal input current (Std): 22.0AInput voltage range (Std): 0...260VInput phases: AC 1 PHDimensions(WxHxD): 88 x 285 x 40 mm
10U5B0B-1010 KEB HF filter 10E5T60-0061 HF radio interference suppression filter in accordance with EN 61800-3for conducted interference***low leakage current***Technical data:C1 - max. motor cable length 10 m to 16 kHzLeakage current: 0.8 mANominal input current (Std): 22.0AInput voltage range (Std): 0...260VInput phases: AC 1 PHDimensions(WxHxD): 88 x 249 x 40 mm
13U5B0D-3030 KEB HF filter 13E5T60-10F1 Internal RFI filter acc. to EN 55011/Bfor conducted interferencefor substructure on KEB COMBIVERT 13.F5. 3 x 400 VFilter current 16 ALeakage current 4.5 mAmax. motor cable 10 mIT mains (low leakage currents) 10 mDimensions W x H x D: 88 x 285 x 40mm
10U5B0B-3000 KEB HF filter 10E5T60-1001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 10 m to 16 kHzC1 - max. motor cable length 30 m to 8 kHzLeakage current: 15 mANominal input current (Std): 8.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 88 x 249 x 40 mm
23U5B0R-3000 KEB HF filter 22E4T60-1001 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 48 mANominal input current (Std): 165AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 270 x 419 x 64 mm
0090425-4133 KEB DU/DT Filtro Umax= 500V Fmax= 800Hz Con realimentación ZK- ABM: 340x75x175 mm Peso: 10kG
20U5B0H-3000 KEB HF-FILTER 20E5T60-1002 HF - Radio interference suppression filter according to EN 61800-3for conducted interferenceTechnical data:C1 - max. Motor cable length 30 m to 16 kHzLeakage current: 15 mANominal input current (Std): 100AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 300 x 445 x 75 mm
17U5B0G-3030 KEB HF filter 17U5T60-10F1 Radio interference suppression filter in accordance with EN 55011/Bfor conducted interferencefor sub/additional installation on KEB COMBIVERT 17.F5. 3 x 400 VFilter current 3 x 50 AIT mains (low leakage currents) 10 mDimensions W x H x D: 181 x 415 x 56mm
19U5B0H-3000 KEB HF filter 19E5T60-1001KEB COMBILINEHF - Radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 16 mANominal input current (Std): 90.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 300 x 445 x 66 mm
15U5B0E-3000 KEB HF filter 15E4T60-1001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 17 mANominal input current (Std): 30.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 132 x 352 x 50 mm
10U5B0D-1000 KEB HF filter 10E5T60-0002 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 12 mANominal input current (Std): 22.0AInput voltage range (Std): 0...260VInput phases: AC 1 PHDimensions(WxHxD): 88 x 285 x 40 mm
15E5T60-A071 KEB EA-Filter 24A EA-FILTER-GEH:E 500V/24A EN55011-B DU/DT:500V/μS 50M MOTORL./ABL.I=20MA FMAX = 100HZ BEI FS=2KHZ PARA FU 15F5 E-GEH. CARCASA ESPECIAL
12U5B0B-3000 KEB RF filter 12E5T60-1001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 20 mANominal input current (Std): 14.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 88 x 249 x 40 mm
14U5B0D-3000 KEB HF filter 14E5T60-1001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 20 mANominal input current (Std): 22.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 88 x 285 x 50 mm
14U5B0D-3030 KEB HF filter 14E5T60-10F2 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:IT network (low leakage currents) 10 mNominal input current (Std): 22.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 88 x 285 x 50 mm
10U5B0B-1000 KEB HF filter 10E5T60-0001 HF radio interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 12 mANominal input current (Std): 22.0AInput voltage range (Std): 0...260Input phases: AC 1 PHDimensions(WxHxD): 88 x 249 x 40 mm
16U5B0E-3030 Filtro KEB HF 16E5T60-10F1 Con kit de montaje EN 55011-B 16.F4 380...480 V versión subestructura/subestructura
14U5B0E-3030 KEB HF filter 14E5T60-10F1 Internal RFI filter in accordance with EN 55011/Bfor conducted interferencefor substructure on KEB COMBIVERT 14.F5. 3 x 400 VFilter current 22 Amax. motor cable 10 mIT mains (low leakage currents) 10 m
18U5B0G-3000 KEBHF filter 18E5T60-1001 HF interference suppression filter in accordance with EN 61800-3for conducted interferenceTechnical data:C1 - max. motor cable length 30 m up to 16 kHzLeakage current: 30 mANominal input current (Std): 65.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 181 x 424 x 65 mm
10U5B0B-3010 KEB HF filter 10E5T60-1061 HF radio interference suppression filter in accordance with EN 61800-3for conducted interference***low leakage current***Technical data:C1 - max. motor cable length 10 m to 16 kHzLeakage current: 4.5 mANominal input current (Std): 8.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 88 x 249 x 40 mm
07U5B0A-1000 Filtro HF KEB 07E5T60-0062
13U5B0D-3010 KEB HF filter 13E5T60-1061 HF radio interference suppression filter in accordance with EN 61800-3for conducted interference***low leakage current***Technical data:C1 - max. motor cable length 10 m to 16 kHzLeakage current: 4.5 mANominal input current (Std): 16.0AInput voltage range (Std): 0...528VInput phases: AC 3 PHDimensions(WxHxD): 88 x 285 x 40 mm
19E5T60-1011 KEB Filtro NHFVersión de montaje lateral NHF Filtro NHF Combinación Filtro EMC EN 55011/ nivel B y reactancia de red uk=4% 400V clase Pn=30kW In=66A Dimensiones 340x110x210 en mm